Steam generators developed by American company Clayton Industries are used as heat recovery marine boilers. Heating surface of the marine heat exhaust boiler is a coil-pipe that consists of a solid spiral pipe. Construction of the coil pipe allows coolant flow in the direction towards the exhaust gasses. The counterflow of steam-water mixture provides the highest rate of heat exchange of the boiler.

Technical datasheet for Clayton heat recovery marine boilers

MODEL EHO-105 EHO-126 EHO-205 EHO-305 EHO-405 EHO-505 EHO-605
Heat output 981 kW (843660 kcal/h) 1226 kW (1054360 kcal/h) 1962 kW (1687320 kcal/h) 2943 kW (2530980 kcal/h) 3924 kW (3374640 kcal/h) 4905 kW (4218300 kcal/h) 5885 kW (5061100 kcal/h)
Steam capacity 1 564 kg/h 1 957 kg/h 3 008 kg/h 4 692 kg/h 6 256 kg/h 7 820 kg/h 9 383 kg/h
Operation pressure 5-30 bar 5-30 bar 10-16 bar 5-28 bar 5-30 bar 5-30 bar 5-30 bar
Efficiency at 100% load diesel 89%
fuel oil 86%
diesel 89%
fuel oil 86%
87% diesel 89%
fuel oil 85%
diesel 87%
fuel oil 85%
diesel 87%
fuel oil 85%
diesel 89%
fuel oil 86%
Efficiency at 75% load diesel 90%
fuel oil 89%
diesel 90%
fuel oil 89%
88% diesel 90%
fuel oil 86%
diesel 88%
fuel oil 86%
diesel 88%
fuel oil 86%
diesel 90%
fuel oil 89%
Efficiency at 50% load diesel 91%
fuel oil 88%
diesel 91%
fuel oil 88%
89% diesel 91%
fuel oil 87%
diesel 90%
fuel oil 88%
diesel 90%
fuel oil 88%
diesel 91%
fuel oil 88%
Efficiency at 25% load 88% diesel 90%
fuel oil 86%
diesel 88%
fuel oil 86%
diesel 88%
fuel oil 86%
diesel 92%
fuel oil 88%
fuel consumption at 100% load diesel 108 l/h
fuel oil 103 kg/h
diesel 135 l/h
fuel oil 129 kg/h
diesel 205 l/h
fuel oil 190 kg/h
diesel 324 l/h
fuel oil 312 kg/h
diesel 442 l/h
fuel oil 417 kg/h
diesel 553 l/h
fuel oil 521 kg/h
diesel 648 l/h
fuel oil 617 kg/h
Heating surface 41,7m2 41,7m2 43,2m2 56,1m2 86,6m2 86,6m2 86,6m2

Coil Pipes for Clayton Marine Boilers

Our company produces coil pipes for the entire lineup of Clayton boilers and offers boiler repair services. Our repair team can perform replacement of boiler coil pipes of Clayton heat recovery marine boilers onboard worldwide.
The coil pipes are produced under the survey of a maritime class society in accordance with vessel registration. The quality of finished products is confirmed by certificates of conformity of corresponding maritime register.